{"product_id":"ecoflow-smart-power-meter","title":"EcoFlow Smart Power Meter","description":"\u003ch3\u003eECOFLOW x Shelly EF-OS-SM003-SMSHEL Energy Meter\u003c\/h3\u003e\n\u003cp\u003eThe EcoFlow x Shelly EF-OS-SM003-SMSHEL energy meter is a three-phase device for monitoring electricity consumption and the load on individual phases. It measures voltage, current, power, active and apparent energy, power factor, as well as active and reactive energy of the fundamental harmonic. It supports current measurement up to 120 A on each phase and the neutral wire using 120 A current transformers (CTs). It offers Wi-Fi and Bluetooth 4.2 connectivity, data logging for at least 60 days, and the ability to export data. Its compact design and DIN-rail mounting facilitate installation in an electrical switchgear.\u003c\/p\u003e\n\u003cp\u003e\n\u003cimg alt=\"EcoFlow Shelly energy meter mounted on a DIN rail, with a visible installation diagram.\" border=\"0\" src=\"https:\/\/assets.innpro.pl\/25853\/34158\/5-a70c20e3-dd90-4f3b-93e1-e510b0dbfedf.jpg\"\u003e\n\u003c\/p\u003e\u003ch3\u003eAccurate measurements and energy consumption monitoring\u003c\/h3\u003e\n\u003cp\u003eThe meter measures voltage in the range of 100–260 V with an accuracy of ±1% and current from 0 to 120 A. In the range of 2–120 A, current measurement accuracy is ±1%. Separate RMS measurements for each phase and the neutral wire allow you to check the load distribution of the installation and identify when energy consumption increases. The device is compatible with 120 A current transformers (CTs), and the minimum load required for calibration between channels is 500 W per channel. The no-load detection threshold is 30 VA per channel.\u003c\/p\u003e\n\u003cp\u003e\n\u003cimg alt=\"EcoFlow x Shelly meter communicating wirelessly with a home photovoltaic system.\" border=\"0\" src=\"https:\/\/assets.innpro.pl\/25853\/34158\/2-52c37977-e4f5-44aa-8f5d-2c1166964adf.jpg\"\u003e\n\u003c\/p\u003e\u003ch3\u003eWi-Fi and Bluetooth Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe EcoFlow x Shelly EF-OS-SM003-SMSHEL supports 2.4 GHz Wi-Fi and Bluetooth 4.2, enabling wireless communication with compatible systems. The Wi-Fi range is up to 30 m indoors and 50 m outdoors, while Bluetooth works at distances of up to 10 m indoors and 30 m in open areas. Actual range depends on environmental conditions. Support for the MQTT protocol, scripts, and webhooks—that is, automatic requests sent to other services—allows the meter to be used in automation systems.\u003c\/p\u003e\n\u003cp\u003e\n\u003cimg alt=\"Diagram showing the integration of the Shelly meter with a home photovoltaic system and the power grid.\" border=\"0\" src=\"https:\/\/assets.innpro.pl\/25853\/34158\/4-42a6170a-07f6-463f-ade3-d46786c37935.jpg\"\u003e\n\u003c\/p\u003e\u003ch3\u003eMeasurement History and Data Export\u003c\/h3\u003e\n\u003cp\u003eThe device stores at least 60 days of measurement data, recorded every minute. This allows you to track how energy consumption changes over specific periods and better manage energy usage. Recorded power quality (PQ) values can be exported to a CSV file, and data in JSON format can be retrieved via the RPC interface. This facilitates further analysis of the results and their archiving.\u003c\/p\u003e\n\u003cp\u003e\n\u003cimg alt=\"The EcoFlow app screen displaying solar energy statistics, along with panels showing consumption charts and system functions.\" border=\"0\" src=\"https:\/\/assets.innpro.pl\/25853\/34158\/6-0e002c9c-f130-44a1-ab7a-efb0096888b5.jpg\"\u003e\n\u003c\/p\u003e\u003ch3\u003eCompact Design and DIN Rail Mounting\u003c\/h3\u003e\n\u003cp\u003eThe meter measures 94 × 19 × 69 mm and weighs approximately 62 g, so it does not take up much space in the switchgear. The white housing is made of plastic, and the screw terminals accommodate wires with a cross-sectional area ranging from 0.5 to 2.5 mm². The recommended wire stripping length is 6–7 mm, and the maximum tightening torque for the terminals is 0.4 Nm. The device requires a power supply of 100–260 V AC, 50\/60 Hz, has a power consumption of less than 3 W, and is equipped with an internal temperature sensor. Installation requires appropriate external protection with class B or C characteristics and a rated current not exceeding 16 A.\u003c\/p\u003e\n\u003cp\u003e\n\u003cimg alt=\"The EcoFlow Shelly three-phase energy meter mounted on a DIN rail, with a diagram visible on the side.\" border=\"0\" src=\"https:\/\/assets.innpro.pl\/25853\/34158\/1-iop-d213f86c-a044-4dae-95fc-4d02a55db2ab.jpg\"\u003e\n\u003c\/p\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eEcoFlow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eEF-OS-SM003-SMSHEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDevice Type\u003c\/th\u003e\n\u003ctd\u003ethree-phase energy meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e94 × 19 × 69 mm (±0.5 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e62 g (±1 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMounting\u003c\/th\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing Material\u003c\/th\u003e\n\u003ctd\u003eplastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eColor\u003c\/th\u003e\n\u003ctd\u003eWhite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupply Voltage\u003c\/th\u003e\n\u003ctd\u003e100–260 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDC Power\u003c\/th\u003e\n\u003ctd\u003eNot supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Consumption\u003c\/th\u003e\n\u003ctd\u003eLess than 3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRMS Voltage Measurement Range\u003c\/th\u003e\n\u003ctd\u003e100–260 V per phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage measurement accuracy\u003c\/th\u003e\n\u003ctd\u003e±1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRMS current measurement range\u003c\/th\u003e\n\u003ctd\u003e0–120 A per phase and neutral wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCompatible current transformer\u003c\/th\u003e\n\u003ctd\u003eCT 120 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent measurement accuracy (2–120 A)\u003c\/th\u003e\n\u003ctd\u003e±1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent measurement accuracy (1–2 A)\u003c\/th\u003e\n\u003ctd\u003e±2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCurrent measurement accuracy (0–1 A)\u003c\/th\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasured parameters\u003c\/th\u003e\n\u003ctd\u003eactive and apparent power, active and apparent energy, power factor, active and reactive energy of the fundamental harmonic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum load for calibration between channels\u003c\/th\u003e\n\u003ctd\u003e500 W per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo-load threshold\u003c\/th\u003e\n\u003ctd\u003e30 VA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInternal temperature sensor\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWi-Fi\u003c\/th\u003e\n\u003ctd\u003eIEEE 802.11 b\/g\/n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrequency band\u003c\/th\u003e\n\u003ctd\u003e2400–2495 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum radio power\u003c\/th\u003e\n\u003ctd\u003eLess than 20 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWi-Fi range\u003c\/th\u003e\n\u003ctd\u003eup to 30 m indoors \/ up to 50 m outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBluetooth\u003c\/th\u003e\n\u003ctd\u003e4.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBluetooth range\u003c\/th\u003e\n\u003ctd\u003eup to 10 m indoors \/ up to 30 m outdoors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProcessor\u003c\/th\u003e\n\u003ctd\u003eESP32-D0WDQ6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlash memory\u003c\/th\u003e\n\u003ctd\u003e16 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement history\u003c\/th\u003e\n\u003ctd\u003eat least 60 days, recorded every minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eData export\u003c\/th\u003e\n\u003ctd\u003eCSV for recorded PQ values, JSON via RPC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMQTT\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eScript support\u003c\/th\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWebhooks\u003c\/th\u003e\n\u003ctd\u003eup to 20, maximum of 5 URLs per webhook\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCoAP\u003c\/th\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAmbient temperature\u003c\/th\u003e\n\u003ctd\u003e-20°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelative humidity\u003c\/th\u003e\n\u003ctd\u003e30–70% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum operating altitude\u003c\/th\u003e\n\u003ctd\u003e2,000 m above sea level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWire cross-section\u003c\/th\u003e\n\u003ctd\u003e0.5–2.5 mm² (20–14 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSupported wires\u003c\/th\u003e\n\u003ctd\u003esolid, stranded, and ferrule-terminated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWire stripping length\u003c\/th\u003e\n\u003ctd\u003e6–7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum terminal tightening torque\u003c\/th\u003e\n\u003ctd\u003e0.4 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRequired external protection\u003c\/th\u003e\n\u003ctd\u003eClass B or C, max. 16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum breaking capacity of the circuit breaker\u003c\/th\u003e\n\u003ctd\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnergy limitation class of the circuit breaker\u003c\/th\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"ECOFLOW","offers":[{"title":"Default Title","offer_id":60456407073093,"sku":"INP-51882","price":219.9,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0970\/8276\/9733\/files\/51882_1_1.webp?v=1795830971","url":"https:\/\/veno.lv\/products\/ecoflow-smart-power-meter","provider":"veno.lt","version":"1.0","type":"link"}